Restoring chiral symmetry to O(a^2) for dynamical Wilson fermions

Roland Hoffmann,Michele Della Morte,Francesco Knechtli,Rainer Sommer,Ulli Wolff
DOI: https://doi.org/10.48550/arXiv.hep-lat/0509077
2005-09-22
Abstract:We present results for the non-perturbative determination of the improvement and renormalization factors of the isovector axial current for lattice QCD with two flavors of dynamical Wilson quarks. The improvement and normalization conditions are formulated in terms of matrix elements of the PCAC relation in the Schroedinger functional setup and results are given in the form of interpolating formulae for bare gauge couplings beta=6/g_0^2>5.2.
High Energy Physics - Lattice
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is: in a low - temperature environment (especially liquid xenon temperature, LXe), find a cheap and simple photosensitive gas detector that can replace traditional photomultiplier tubes (PMs) or avalanche solid - state detectors for liquid xenon time - projection chambers (LXe TPCs) in dark matter detection. Specifically, the paper mainly focuses on the following aspects: 1. **Detector operating stability**: Study the operating performance of photosensitive gas detectors (including linear and hole - type detectors) in the temperature range from 300K to 150K, especially their long - term stability. This includes both sealed and gas - filled detectors. 2. **Quantum efficiency (QE)**: Evaluate the quantum efficiency of different types of cesium iodide (CsI) photocathodes (reflective and semi - transparent) in a low - temperature environment and verify whether they can meet the application requirements of LXe TPCs. 3. **High - gain performance**: Test whether these detectors can achieve sufficient gain at low temperatures to detect single - photoelectron signals, thereby improving the signal - to - noise ratio. 4. **Cost - effectiveness and radioactive background**: Explore the cost - effectiveness of these new detectors and their impact on the overall system radioactive background, in order to find a more economical and safer alternative. Through these studies, the author hopes to prove that photosensitive gas detectors can work stably in a low - temperature environment and have sufficient sensitivity and stability to become an effective substitute for photomultiplier tubes in future LXe TPCs. ### Key conclusions: - **Stability of sealed detectors**: Sealed photosensitive gas detectors exhibit extremely high long - term stability, and the quantum efficiency has hardly changed after one and a half years of testing. - **Gain characteristics**: The maximum achievable gain of linear detectors increases as the temperature decreases, while the maximum gain of bare - hole detectors decreases significantly. - **Quantum efficiency**: The semi - transparent CsI photocathode shows better light - collection performance at low temperatures, which helps to improve the overall performance of the detector. - **Possibility of cascaded detectors**: Although the gain of a single - hole detector is low, a higher gain can be achieved by cascading multiple detectors to meet the need for single - photoelectron detection. These results indicate that photosensitive gas detectors have the potential to become key components in LXe TPCs, especially having obvious advantages in reducing costs and radioactive backgrounds.