Is the diastolic shock index of value in the intra operative management of cardiac surgical patients?

Kanishka Indraratna
DOI: https://doi.org/10.1016/j.jcrc.2024.154751
IF: 4.298
2024-04-01
Journal of Critical Care
Abstract:Introduction and aim Diastolic shock index (DSI) is a new measurement of vasodilatation which can be used to identify a poor prognosis in septic shock.(1) DSI is dividing the heart rate by the diastolic pressure. If over 2.2 it indicates vasodilation in septic shock. This measurement has not been validated for therapeutic intervention in septic shock.(1) These measurements are always available during cardiac surgery. The assessment of vasodilatation and the haemodynamic management can be made by measuring the ventricular-arterial coupling ratio with transesophageal echo. The measurements with transesophageal echo needs expertise and a simpler continuous measurement such as the diastolic shock index would be advantageous. This study compares the correlation between the two methods, and its validity in cardiac surgery. Patients and methods All patients presenting for cardiac surgery and being anaesthetised by the author were recruited. The patients were anaesthetised and monitored according to established practice. If and when the mean arterial pressure fell below 65 mmHg during the procedure, the coupling ratio and the diastolic shock index were measured. Analysis was done to compare whether the diastolic shock index was comparable to the information available from the ventricular -arterial coupling ratio. Results 25 measurements were taken when the MAP was less than 65 in a series of patients. With the MAP less than 65 the DSI was over 2.2 in only 2 patients.(8%) The coupling ratio showed vasodilatation in 64% and decoupling in 20%. There were 84% abnormal ventricular coupling ratios. There were also 40% who showed fluid deficit and fluid responsiveness.36% showed both low coupling ratio and fluid deficit and responsiveness. 4% showed only fluid deficit and responsiveness. The patients were managed according to the information obtained from the ventricular-arterial coupling ratio with fluids, vasopressors and inotropes. There was good response and no mortality. Conclusion There is no relationship between the coupling ratio and the DSI. The DSI cannot be used to identify the cause of low blood pressure in patients under going cardiac surgery and also cannot be used to guide therapy in the presence of low blood pressure during cardiac surgery. References 1. Ospina-Tascon G A, Teboul JL, Hernandez G et al. Diastolic shock index and clinical outcomes in patients with septic shock. Ann. Intensive Care 2020. 10, 41
critical care medicine
What problem does this paper attempt to address?