Probing subtle fluorescence dynamics in cellular proteins by streak camera based Fluorescence Lifetime Imaging Microscopy

R.V. Krishnan,Eva Biener,Jian-Hua Zhang,Robert Heckel,Brian Herman
DOI: https://doi.org/10.1063/1.1630154
2003-09-27
Abstract:We report the cell biological applications of a recently developed multiphoton fluorescence lifetime imaging microscopy system using a streak camera (StreakFLIM). The system was calibrated with standard fluorophore specimens and was shown to have high accuracy and reproducibility. We demonstrate the applicability of this instrument in living cells for measuring the effects of protein targeting and point mutations in the protein sequence which are not obtainable in conventional intensity based fluorescence microscopy methods. We discuss the relevance of such time resolved information in quantitative energy transfer microscopy and in measurement of the parameters characterizing intracellular physiology.
Cell Behavior
What problem does this paper attempt to address?
The problems that this paper attempts to solve mainly focus on detecting the subtle fluorescence kinetic changes of intracellular proteins through the use of Streak - based Fluorescence Lifetime Imaging Microscopy (StreakFLIM) technology. Specifically, the researchers hope that through this technology, they can measure the influence of protein targeting and single - amino - acid changes in protein sequences on fluorescence lifetime, which cannot be obtained in traditional intensity - based fluorescence microscopy methods. The paper explores the following three specific problems: 1. **Does the construction of fusion proteins affect the measured fluorescence lifetime of ECFP?** - The researchers constructed ECFP fused with Bax protein (Bax - ECFP) and measured its fluorescence lifetime through the FLIM system to evaluate the influence of the fusion protein on fluorescence characteristics. 2. **When ECFP is targeted to specific organelles within the cell, will its fluorescence lifetime be different?** - By targeting ECFP to the cell membrane (mem - ECFP) or mitochondria (mito - ECFP), the researchers hope to understand the influence of different cellular environments on the fluorescence lifetime of fluorescent proteins. 3. **Can fluorescence lifetime measurement detect the fluorescence decay changes caused by single - amino - acid changes in the ECFP protein sequence?** - To verify this, the researchers introduced a mutation (A207K) known to reduce the dimerization of fluorescent proteins and compared the fluorescence lifetimes of wild - type ECFP and mutant - type ECFP (mut - ECFP) to observe the specific influence of single - amino - acid changes on fluorescence kinetics. The solutions to these problems not only help to understand the behavior of fluorescent proteins in different cellular environments but also can provide more accurate data support for quantitative imaging techniques such as Fluorescence Resonance Energy Transfer (FRET) microscopy, thereby better quantifying and describing physiological parameters within the cell.