High nuclear polarization of helium-3 at low and high pressure by metastability exchange optical pumping at 1.5 Tesla

Marie Abboud,Alice Sinatra,Xavier Maitre,Genevieve Tastevin,Pierre-Jean Nacher
DOI: https://doi.org/10.1209/epl/i2004-10237-y
2004-09-22
Abstract:We perform metastability exchange optical pumping of helium-3 in a strong magnetic field of 1.5 T. The achieved nuclear polarization, from 80% at 1.33 mbar to 25% at 67 mbar, shows a substantial improvement at high pressures with respect to standard low-field optical pumping. The specific mechanisms of metastability exchange optical pumping at high field are investigated, advantages and intrinsic limitations are discussed. From a practical point of view, our results open the way to alternative technological solutions for polarized helium-3 applications and in particular for magnetic resonance imaging of human lungs.
Atomic Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: How to achieve efficient nuclear polarization of 3He gas by the metastable - exchange optical pumping (MEOP) technique under a high magnetic field (1.5 Tesla), especially under high - pressure conditions. Specifically, the research aims to overcome the inefficiency of the standard low - field optical pumping method under high pressure and provide a more efficient method for producing polarized 3He gas for medical applications (such as pulmonary magnetic resonance imaging). ### Main problem summary: 1. **Improve the polarization rate**: Under standard conditions, MEOP is usually carried out at low pressure (1 mbar) and in a low magnetic field (about 1 mT), and the polarization rate will drop significantly under high pressure. Therefore, researchers hope to obtain a high polarization rate even at higher pressures. 2. **Simplify the compression process**: For medical applications, especially MRI, the polarized 3He gas needs to be compressed to atmospheric pressure. If the polarized gas can be directly obtained at a higher pressure, this compression process can be greatly simplified. 3. **Improve production efficiency**: Under a high magnetic field, can the production rate of polarized gas be improved by improving the optical pumping scheme, making it more suitable for large - scale production and clinical applications? ### Research background: - **Applications of polarized 3He**: Polarized 3He gas has important applications in multiple scientific fields, including statistical physics, nuclear physics, biophysics, and medicine. Especially in medicine, polarized - gas magnetic resonance imaging is a new tool for diagnosing lung diseases. - **Limitations of existing methods**: Currently, there are two main polarization methods: spin - exchange and optical pumping of alkali - metal atoms, and pure helium metastable - exchange optical pumping (MEOP). MEOP under standard conditions performs well at low pressure and in a low magnetic field, but it has poor performance under high pressure and requires an additional compression step to reach the required density. ### Solutions: - **MEOP under a high magnetic field**: Researchers conducted experiments in a strong magnetic field of 1.5 Tesla and found that this method can significantly improve the polarization rate under high pressure. For example, a polarization rate of about 80% can be obtained at 1.33 mbar, and 25% can still be maintained at 67 mbar, which is much higher than the results in a low magnetic field. - **Mechanism exploration**: By establishing a simple rate - equation model, researchers explained the reasons for the increase in the polarization rate under a high magnetic field, mainly due to the selective excitation and hyperfine decoupling effects caused by Zeeman splitting, which suppress the unnecessary relaxation channels. ### Experimental results: - **Polarization rate and establishment time**: Under different pressures and laser powers, the experimental results show the changing trends of the polarization rate and establishment time. Under a high magnetic field, the polarization rate increases with increasing pressure, and the establishment time is relatively short. - **Production efficiency**: Although the production efficiency at low pressure is not as good as that in a low magnetic field condition, at a relatively high pressure (such as 32 mbar), the production efficiency is significantly improved and can meet the needs of small - animal lung imaging. ### Future prospects: - **Further verification of hypotheses**: Plans are made to conduct more experiments at different magnetic field intensities to verify the specific mechanism for the increase in the polarization rate under a high magnetic field. - **Practical applications**: Develop a 3He polarizer suitable for MRI that can work efficiently under a 1.5 - Tesla magnetic field and a pressure of tens of mbar, thereby simplifying the production and compression processes of polarized gas and promoting its wide application in the medical field. In conclusion, this research shows that the MEOP technique under a high magnetic field significantly improves the polarization rate and production efficiency of 3He gas under high - pressure conditions, providing new possibilities for future medical applications.