Long-Term Surgical Outcomes of Glaucoma Drainage Implants in Eyes with Preoperative Intraocular Pressure Less than 19 mmHg

Shahin Hallaj,Jae-Chiang Wong,Lauren E. Hock,Natasha Nayak Kolomeyer,Aakriti G. Shukla,Michael J. Pro,Marlene R. Moster,Jonathan S. Myers,Reza Razeghinejad,Daniel Lee
DOI: https://doi.org/10.1155/2024/6624021
2024-01-25
Journal of Ophthalmology
Abstract:Background. This retrospective review reports on patients who underwent glaucoma drainage implant (GDI) surgery and had baseline intraocular pressure (IOP) of ≤18 mmHg with at least one year of follow-up. Methods. Clinical data of 67 eyes of 67 patients were collected from patients' charts, and the outcomes of GDI were evaluated until 7 years. GDI failure was defined as IOP reduction of less than 20% from the baseline at two consecutive visits three months after surgery, decline to no light perception, or if additional glaucoma surgery was performed. Results. The average age was 65.9 ± 13.2 years. Most cases were male (52.2%), White (53.7%), and had primary open-angle glaucoma (62.7%). Forty-four eyes had prior glaucoma surgery (68.6%) and 46 (68.6%) had severe glaucoma. Though postoperative (postop) IOP changes were insignificant, the average postop number of medications dropped from 2.4 ± 1.4 to 1.9 ± 1.2 medications two years after surgery ( p=0.0451 ). Postop complications (23.9%) included GDI exposure (7.5%), inflammation (4.5%), shallow anterior chamber (4.5%), and strabismus (1.5%). Hypotony was observed in 4 eyes (5.9%), none of which developed hypotony maculopathy. The cumulative one-year failure rate was 56.7%, most of which were due to failure to lower IOP. Conclusion. In patients with baseline IOP ≤18 mmHg who had GDI surgery, though the change in IOP was not statistically significant, the number of medications dropped and visual field progression slowed in a subset of patients with adequate perimetric data. Due to a relatively high rate of complications and limited effectiveness in lowering IOP, GDI should be cautiously used in these eyes.
ophthalmology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the long - term efficacy and safety of using glaucoma drainage implant (GDI) surgery in glaucoma patients with preoperative intraocular pressure (IOP) less than 19 mmHg. Specifically, the study aims to evaluate the long - term intraocular pressure changes, drug use, visual field progression, and complication incidence in these patients after GDI surgery, so as to provide support for clinical decision - making. The research background points out that it is difficult to manage the condition of glaucoma patients with low preoperative intraocular pressure but continuous deterioration of the visual field, so it is necessary to explore the application effect of GDI surgery in this specific population. The paper evaluated the efficacy of GDI surgery in reducing intraocular pressure, reducing drug use, and delaying visual field deterioration by retrospectively analyzing the clinical data of 67 patients, and reported the occurrence of postoperative complications. The research results show that although GDI surgery failed to significantly reduce intraocular pressure, it reduced the number of intraocular pressure - controlling drugs required by patients and slowed down the visual field deterioration rate of some patients to a certain extent. However, GDI surgery also has a relatively high complication rate in this population, suggesting that careful consideration is required when choosing this treatment method.