M. Martinelli,K.S. Zhang,T. Coudreau,A. Maitre,C. Fabre
Abstract:We have operated a CW triply resonant OPO using a PPLN crystal pumped by a Nd:YAG laser at 1.06 micron and generating signal and idler modes in the 2-2.3 micron range. The OPO was operated stably in single mode operation over large periods of time with a pump threshold as low as 500 microwatts.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a continuous - wave (CW) triple - resonant optical parametric oscillator (OPO) with an extremely low threshold in the near - infrared region (2 - 2.3 μm), and use periodically poled lithium niobate (PPLN) crystals as the nonlinear medium. Specifically, the authors aim to:
1. **Reduce the pump threshold of the OPO**: By optimizing the cavity design and material selection, the OPO can be started at a lower pump power and maintain stable single - mode operation.
2. **Achieve an efficient and stable near - infrared light source**: Generate signal and idler light modes in the 2 - 2.3 μm wavelength range, which is very important for molecular spectroscopy and lidar (LIDAR) applications.
3. **Verify the theoretical model**: Verify the theoretically predicted threshold formula through experimental data, and explore the changes in OPO performance under different temperature and cavity length conditions.
### Key technical points
- **Periodically poled lithium niobate (PPLN) crystal**: It provides a large nonlinear coefficient, enabling efficient OPO operation even in the frequency range with low phase - matching efficiency.
- **Triple - resonant OPO**: It is simultaneously resonant in three modes of pump light, signal light, and idler light, thus significantly reducing the threshold.
- **Low - loss optical cavity design**: High - reflectivity mirrors and anti - reflection coatings are used to reduce the intracavity loss and further reduce the threshold.
### Main achievements
- **Extremely low threshold**: A pump threshold lower than 500 μW has been achieved, which is much lower than similar devices in the past.
- **Stable operation**: It can operate stably for a long time, and the output power fluctuation is small.
- **Consistency between theory and experiment**: The experimental results are basically consistent with the theoretical predictions, verifying the validity of the formula used.
### Relevant formulas
1. **Threshold power formula**:
\[
P_{\text{threshold}} = \frac{(T_p + L_p)^2 (T_s + L_s) (T_i + L_i)}{64 T_p \chi^2}
\]
where \( T_p, L_p, T_s, L_s, T_i, L_i \) are the intensity transmission and loss coefficients of the pump, signal, and idler modes respectively, and \(\chi\) is the effective nonlinear coefficient.
2. **Output power formula**:
\[
P_{\text{out, signal}} = \frac{\hbar \omega_{\text{signal}} T_s (T_i + L_i) (T_p + L_p)}{16 |\chi'|^2 \left( \sqrt{\frac{P_{\text{pump}}}{P_{\text{threshold}}} - 1} \right)}
\]
These formulas are used to describe the threshold and output characteristics of the OPO, helping to understand its working principle and performance optimization direction.